ApkDownload

SCADAfeathery for Modbus APK

Latest Version V for Windows
Updated 2023-02-12

App information

Version V (#10)

Updated 2023-02-12

APK Size 4.8 MB

Requires Android Android 10+ (Android 10)

Offered by AutomationServices

Category Free Productivity App

App id com.automationservices.scadafeathery

Developer's notes SCADA with simple handling for modbus-networks, optimized for WAGO-Devices.

Screenshot

Click on the image to see full size

Latest updates

What's new in SCADAfeathery for Modbus V

Bugfix for dark mode

Editor's review

Download the latest SCADAfeathery for Modbus application, version V, compatible with Windows 10/11 (using emulators such as Bluestacks), Android devices. This free Productivity app is developed by AutomationServices and is easy to download and install.

Previous versions, including V, are also available. If you need help or have any problems, please let us know.

Description

You have a Modbus device and want to visualize it by a few easy steps?
Are you an owner of WAGO (P-)FC series 750/758?
Are your writing CoDeSys 2.3 programms on WAGO-devices and want to
see the calculation results on your android device?
Then this application is that what you are looking for.
After only 3 steps the definition of the visualization is complete:
1) Define your Modbus network.
2) Create data points.
3) Define the representation of the data points

You can define any number of devices on the network.
The devices (called network services) are stored in the application,
and can be used later.
For each device (network service), you can assign its data points.
The definition of a datapoint consists of the following parameters:
- Designation of the datapoint

- Datatype of the datapoint (based on IEC61131-Datatypes)
- Datatype STRING requiers the length in bytes additionaly
- Read-Defintion: FC-Code (FC1, FC2, FC3, FC4)
- Read-Definition: modbus address (register or coil, depends on FC-Code)
- Read-Definition: bit offset, within the addressed modbus register or coil
- Write-Defintion: FC-Code (FC5, FC6, FC15, FC16)
- Write-Definition: modbus address (register or coil, depends on FC-Code)
- Write-Definition: bit offset, within the addressed modbus register or coil

For WAGO-Devices this parameters are filled out automaticaly.

Each data point can be visualized by (at the moment) 4 presentation items:
+ Textbox
+ Slider (0..100)
+ Switch
+ XY-Plot
Your are able to scale the values by the linear polynom (f(x)=m*x+b).
You can define min/max-ranges, that are monitored at the runtime.
There is a constant monitoring of the data point availability , you will be notified
if the datapoint is not accessable anymore.


Modbus-communication

The communication is possible through Wifi and 3G/4G- Networks.
Following modbus function codes are supported:
FC1, FC2, FC3, FC4,FC5,FC6,FC15,FC16.
An real-time algorithm used for communication task guarantees that the calculated
cycle-time for each communication-job will be kept.
The cycle-time is linearly proportional to the number of datapoints within the perspective.



Special features for WAGO-Devices

This appliation contains a database with all at the moment existing WAGO-Controllers and Couplers
of the series 750/758. There is also modbus process image data about all terminals of the series 750/753.

You have defined your WAGO node already as network service?
Then mark the discovered devices as WAGO device and scan the node.
The connected terminals will be recognized and the full process image for modbus will be stored.
Now you no longer have to calculate the address of the terminal in the process image.
Just select the terminal and the channel of the terminal from the node description and make it to
a data point.
Do you have a PFC (programmable WAGO coupler)? Then it is possible to you to define a datapoint just by
entereing of the IEC61131-address. Just enter the %I, %Q, %M address of your programm variable and the application
converts this information into accoridn modbus-address on the network.
Hint: Consider the PI-Assignment-Setting from CoDeSys if you want the write-access to kbus-terminals.

App permissions

SCADAfeathery for Modbus V APK requires following permissions:

Allows applications to open network sockets.

Allows applications to enter Wi-Fi Multicast mode.

Ratings and Reviews

Rating: 5.0/5 based on Less than 100 reviews

(*) is required

Previous versions

SCADAfeathery for Modbus V APK for Windows (#10, 4.8 MB)